Adaptive filtering to reduce global interference in non-invasive NIRS measures of brain activation: how well and when does it work?
In previous work we introduced a novel method for reducing global interference, based on adaptive filtering, to improve the contrast to noise ratio (CNR) of evoked hemodynamic responses measured non-invasively with near infrared spectroscopy (NIRS). Here, we address the issue of how to generally apply the proposed adaptive filtering method. A total of 156 evoked visual response measurements, collected from 15 individuals, were analyzed. The similarity (correlation) between measurements with far and near source-detector separations collected during the rest period before visual stimulation was used as indicator of global interference dominance. A detailed analysis of CNR improvement in oxy-hemoglobin (O(2)Hb) and deoxy-hemoglobin (HHb), as a function of the rest period correlation coefficient, is presented. Results show that for O(2)Hb measurements, 66% exhibited substantial global interference. For this dataset, dominated by global interference, 71% of the measurements revealed CNR imp