Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Can I use ARTeMIS Extractor to perform classical structure testing, such as those with knowing excitation force? Is there any limitation for number of channels?

0
Posted

Can I use ARTeMIS Extractor to perform classical structure testing, such as those with knowing excitation force? Is there any limitation for number of channels?

0

ARTeMIS Extractor is only for modal analysis based on measured responses. If known excitation forces are used the software can still be used to analyze the responses. However, the excitation itself cannot be taken into account, which means that the mode shapes always will be unscaled. The software has been tested with 350 channels measured simultaneously at 12.5 kHz for 90 seconds. If more measurement channels are needed it is recommended to split the measurements into more data sets keeping a few sensors at fixed reference positions.

Related Questions

What is your question?