Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

CAPWAP, PDA, GRLWEAPMy CAPWAP analysis is showing a total capacity (Ru) greater than the applied force (FMX). Is that possible?

0
10 Posted

CAPWAP, PDA, GRLWEAPMy CAPWAP analysis is showing a total capacity (Ru) greater than the applied force (FMX). Is that possible?

0
10

Theoretically, for a fixed end pile (no skin friction and infinite end bearing) the mobilized capacity would be equal to two times the impact force. In practice a mobilized capacity higher than about 1.3 times the impact force is unusual, and it is very unlikely that the mobilized capacity could exceed 1.6 times the impact force (FMX).