Could the filter cloth of industrial filters be used in the Sepa filtrations units, after cutting it to proper size?
A. The Sepa CF can potentially work for any media that can be fitted into the chamber. One thing that could be an issue for some types of filter media is whether or not a sufficient seal is made between the O-ring and the media. For membranes, this is not a problem because membranes have a relatively smooth surface, which affords good mechanical seal when pressed together. A large fiber woven material, for example, may need to be modified or filled with some type of potting compound to level the surface in order to get a non-bypass seal.