Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Do characters typed into the computer continue echo in the Terminal screen – even when the jumper wire shorting RX to TX is disconnected?

0
Posted

Do characters typed into the computer continue echo in the Terminal screen – even when the jumper wire shorting RX to TX is disconnected?

0

— An echo will indicate an internal cable short, or an incorrect COM-port configuration. If so, replace the RS232 cable. FINAL SOFTWARE CHECKS IN XWARE 1) If the loop-back test is successful, verify in X-Ware that the correct product is selected. In SETTINGS, verify that the proper PC COM port and device address is selected, that Baud is 9600, Data Bits=8, Stop Bits=1, and Parity=none. 2) Click on the CHECKOUT box under SETTINGS. The response should be “Port Checks out Fine”. Click OK. Click OK again in the SETTINGS dialog screen to exit. Click on CONNECT.