Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Does the QRS116 have any overrange capability?

capability overrange qrs116
0
10 Posted

Does the QRS116 have any overrange capability?

0
10

The model QRS116 has a built-in overrange capability of a minimum of 120% of the stated full scale output. For example, a QRS116 with a ±120°/second. At some point above ±120°/second, the output signal will reach its limit, and remain in this “saturated” condition until the overrange angular rate is no longer present. During the time the overrange rate is present, the output signal will remain stable and will not “fold-back”. When the angular rate drops below the point of saturation, the output signal will once again indicate the true angular rate. Extremely high angular rates (e.g., 5,000 to 10,000°/sec, or more) will not damage the Model QRS116.