Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Does the type of exterior sheathing need to be noted or play any role?

exterior noted play sheathing type
0
Posted

Does the type of exterior sheathing need to be noted or play any role?

0

If no insulated sheathing is entered (entered in the software as continuous insulation), the sheathing is assumed to be plywood with an R-value of 0.83. If insulated sheathing is used, only 80% of the net wall is assumed to be covered by the insulating sheathing. The other 20% is assumed to be covered with plywood (R-value = 0.83). If you choose “other” as the assembly type, you must enter the U-factor of the entire assembly and be prepared to provide the backup specifications to the building official as to how the U-factor was derived.