Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

For a unit that has an O2 monitor and doesn’t meet the conditions required to use Tier 4, but elects to use Tier 4, what are the monitoring requirements?

0
Posted

For a unit that has an O2 monitor and doesn’t meet the conditions required to use Tier 4, but elects to use Tier 4, what are the monitoring requirements?

0

If a facility elects to use Tier 4, then all of the Tier 4 requirements must be met. In this case, a stack flow monitor must be installed and certified, and the O2 monitor may be used in lieu of installing and certifying a CO2 monitor, provided that: (1) only fuels listed in Table 1 in section 3.3.5 of Part 75, Appendix F are combusted in the unit; and (2) the effluent stream does not include any CO2 emissions from non-combustion processes or emission control systems. (See §98.33(a)(4)(iv)). However, the RATA of the O2 monitor must be conducted on a %CO2 basis comparing the calculated CO2 concentrations to the CO2 reference method.