How can I import data into ARTeMIS Extractor ?
There are three ways to do it: SVS Configuration File, which is a text file with information about the geometry, DOF information (nodal positions and directions of the measurement channels) and links to the files containing the data. Universal File Format (UFF). This is an alternative way to initialize a project. Universal File Format is the industry standard format for file storage of geometry, DOF information and measurements. We support both ASCII and binary format. OLE Automation. If you have an application that supports OLE Automation, like Visual Basic, MATLAB, Excel, LabView, then the ARTeMIS Extractor has an OLE interface called ARTX.Document that can be used to implement direct transfer of geometry, DOF information and measurements from you own application.