How do I deal with a bearing(s) that are much larger than the rest of the group?
If a master divider + secondary divider distribution system is in use, the lube points with the largest hourly volume requirements may need to be serviced from the master divider in order to provide the larger required volumes. Alternatively, cross-porting two or more sections of a divider assembly together can achieve volume outputs that are beyond the range of a single valve section.