Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How does one set timer 2/3 module to the synchronous counter mode?

0
Posted

How does one set timer 2/3 module to the synchronous counter mode?

0

Prescaler 1:1 is selected, external clock is enabled TCS=1, 32-bit operation is enabled T32=1, the operation of the timer1 module is enabled TON=1 in the control register T2CON (in 32-bit operation the control bits T3CON are ignored), interrupt bits of timer2/3 module are set (in the concatenated timer2/3 interrupts are controlled by the control bits of timer3 module), priority of interrupts T3IPC=1, interrupt request bit T3IF=0, and interrupt enable bit T3IE=1.