How much fill gas is added?
After the lamp has been processed, it is evacuated and back-filled with high-purity neon or argon. The fill gas pressure is carefully selected to give the optimum balance between lamp intensity and useful operating life. Argon is only used when a neon spectral line would interfere with the wavelength for the selected element.