How to do media calibration?
Procedure: 1. X & G-Series: 1.1. Turn off power 1.2. Press and Hold the “PAUSE / CALIBR.” button then turn on power, do not release the button until the message “CALIBRATION…” shown on the LCD display and several labels feed then stop. 1.3. Press “FEED” button several times to feed labels in order to make sure the label gap or black line has been correctly detected. 2. R-Series 2.1. Turn off power 2.2. Press and Hold the “PAUSE” button then turn on power, do not release the button until several labels feed then stop. 2.3. Press “FEED” button several times to feed labels in order to make sure the label gap or black line has been correctly detected. 3. OS-Series 3.1. Turn off power 3.2. Press and Hold the “FEED” button then turn on power again, do not release the button until several labels feed. (The procedure to do OS-Series calibration is similar to printing configuration pattern, but the “FEED” button released timing differs. To print configuration pattern the “FEED” button will be