Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

I generated a .modl file for CZ2D analysis that has several conductors, but the output appears to be missing one or more conductors in the output. What could cause this?

0
Posted

I generated a .modl file for CZ2D analysis that has several conductors, but the output appears to be missing one or more conductors in the output. What could cause this?

0

Make sure that the cutting plane is specified correctly, so that, for example, if the signal lines run along the y direction, the cutting plane specified is “Y” and that all the signal lines pass through the y location given in the entry field. In addition, make sure that each conductor has a group number associated with it and that the reference conductor(s) have a group number that is the largest from the set of group numbers. It is recommended that reference conductors be given an easily-identified group number, such as 99.