Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is an additional fire valve required for an oil fired vaporising range cooker?

0
Posted

Is an additional fire valve required for an oil fired vaporising range cooker?

0

Yes, two fire valves are generally required for an oil fired vaporising range cooker installations. One for the protection of the cooker and one for the protection of the oil float control valve. Cooker installations that also incorporate an oil lifter would require a third remote acting fire valve. (see OFTEC Technical Book 3 2010) Your local OFTEC Registered Technician would be able to advise on the most appropriate protection methods for the installation. For details of OFTEC Registered Technicians that operate local in your area, please see Locate a Registered Company.