Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Minimum depth requirement for sewer, gas, water, and electrical lines/conduits?

0
Posted

Minimum depth requirement for sewer, gas, water, and electrical lines/conduits?

0

Sewer line depth: 12″ of cover measured from the top of pipe. Gas line depth iron pipe: 12″ of cover measured from the top of pipe. Gas line depth poly pipe: 18″ of cover measured from the top of pipe. Water line depth: 12″ of cover measured from the top of pipe. Electrical line depth: 18″ of cover measured from the top of pipe.