What happens if the shaft contacts the auxiliary bearing due to a large transient load greater than the bearing capacity?
The bearing does not shutdown in this situation but will continue to produce its maximum rated load (i.e., it will “load share” with auxiliary bearing). Once the transient load is removed, the bearing controller will automatically regain control of the shaft and center it within the magnetic bearing.