Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What insulation is required on heating and cooling ducts?

0
Posted

What insulation is required on heating and cooling ducts?

0

If located outside of the thermal envelope (for example, in a ventilated attic) supply and return ducts, plenums and boots must be insulated to R-8. If 14 SEER or higher equipment is installed, R-6 plenums and boots are allowed. For ducts located within the thermal envelope (for example, between the floors of a two-story house or apartment) R-4.2 is acceptable.