Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the best method of supplying electric to a wooden garden shed?

0
Posted

What is the best method of supplying electric to a wooden garden shed?

0

to supply electricity to any outside building firstly requires a means of isolation at both ends so the shed end would require a distribution board of some sort and fitted with an RCD to prevent electric shock,also the house end should ideally have an RCD as well which could already be in the house board. You cannot fix the wiring to a fence as it is not permitted by regulations so you either need to bury armoured cable and would suggest 3 core 1.5 or 2.5 which requires special termination glands or an overhead cable which would require a wire catenary to support it . Really its a job for a proffesional spark as there are many risks involved with electricity and they tend only to be fatal once.