Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the effect of the P43® on tank internals such as heating coils, roof drains and water drawoff lines?

0
Posted

What is the effect of the P43® on tank internals such as heating coils, roof drains and water drawoff lines?

0

Care should be taken in the installation of the P43® to ensure that the centre line of the jet does nto directly impact tank internals in the vicinity of the P43®, as this would reduce the penetration of the jet. For purposes of doing a detailed structural analysis on the impact of the jet on tank internals, the following equation may be used to determine the centre-line velocity of the jet at any distance from the P43®: U = 0.1776 x Q/KD Where U = Jet Centre Line Velocity (Ft/Sec) Q = Flow per Nozzle (USGPM) X = Distance from Nozzle (Feet) D = Nozzle Diameter (Inches) Based upon our operating experience to date, no damage has occurred to roof drains or water drawoff lines resulting from the P43®. Tank internals should be secured from drifting off supports, in most cases this has already been done with U-Bolts.