Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the minimum height I can project without it to be considered as audience scanning?

0
Posted

What is the minimum height I can project without it to be considered as audience scanning?

0

HSG95 states that installations should be designed so that the any point less than 3m above and 2.5m laterally from any location that the public has access to should not contain laser radiation that exceeds the MPE level. If the projection area has a raised floor or podiums, the 3m measurement is to be considered from the floor of the raised area.