Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What pressures should be used in the remote fire gas gun volume chamber?

0
Posted

What pressures should be used in the remote fire gas gun volume chamber?

0

The remote fire gas gun volume chamber should normally be pressurized to 200 PSI in excess of well pressure. The gas gun, when energized, should supply a gas pulse which travels through the casing annulus gas and reflects from the collars and the liquid level. The pulse should reflect from all collars and the liquid level and an optimum acoustic data set would consist of collar reflections from the surface to the liquid level with a distinct liquid level reflection. Acoustic collar response from the surface all of the way to the liquid level is not required since the computerized Well Analyzer will filter the acoustic data and extrapolate from known collar responses down to the liquid level. However, the measured liquid level depth is more accurate when a maximum number of collar reflections are obtained. The minimum acceptable acoustic data set would give a few collars and a liquid level response. In general, the more pressure that is used in the gas gun volume chamber, the further do

Related Questions

What is your question?