Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

When a Flash timing excess was detected by the timing limit excess flag DQ5 (DQ6 = “toggle” and DQ5 = “1”), does the RDYINT bit become “1”?

0
Posted

When a Flash timing excess was detected by the timing limit excess flag DQ5 (DQ6 = “toggle” and DQ5 = “1”), does the RDYINT bit become “1”?

0

• Answer :When a Flash timing excess is detected by the timing limit excess flag DQ5 (DQ6 = “toggle” and DQ5 = “1”), neither the RDYINT bit nor RDY bit becomes “1.” Therefore, the Flash error status (timing limit excess) cannot be detected by the Flash memory control status register (FMCS). It can be detected only by the Flash hardware sequence flag.