Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

When using the HT9020 datasheet application circuit to interface to the telephone line, why can I not decode CPT data?

0
Posted

When using the HT9020 datasheet application circuit to interface to the telephone line, why can I not decode CPT data?

0

Answer Because the telephone line terminal has no reference ground, the HT9020 has no way to correctly decode the data. The supplied telephone terminal should be connected to a bridge rectifier, who’s reference ground should be connected to the reference ground of the application circuit, to solve this problem.