Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Where in the negative lead do I install currents shunts?

0
Posted

Where in the negative lead do I install currents shunts?

0

The SP PRO can allow 2 external current shunts. No current shunt is required to measure the SP PRO’s current. If a shunt is being used for a charging source eg, Solar, Wind or Hydro, the current shunt must be placed between the regulating device and the battery. If a current shunt is placed between the charge source and the regulating device, then the current reading may be incorrect.