Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why isn’t there any metering or clipping indicators on the MA-4HP?

0
Posted

Why isn’t there any metering or clipping indicators on the MA-4HP?

0

Since there are several standards for full scale digital, metering is best left to the device being fed. Additionally, as the clip point of the MA-4HP exceeds +30dBm (with a minimum gain of 8.5dB this equates to greater than +21dBu input level handling) clipping is unlikely to occur and additional circuitry would increase the cost of the unit.