Can meters be used with piston type pumps?

meters piston Pumps type Used
0
Posted

Can meters be used with piston type pumps?

0

The Model 1100 turbine meter works well in this application compared to other invasive measurement devices. However, due to constant pulsation of the fluid, the QuikSert meter may be a better choice due to its design. Depending on the back pressure and how close the Model 1100 meter is to the pump, the snap rings can wear and cause loss of components downstream. In all cases for invasive style meters, pulsation should be kept to a minimum.