Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why do I see detections with identical millisecond timestamps in my MiniMon data files?

0
Posted

Why do I see detections with identical millisecond timestamps in my MiniMon data files?

0

The redundant milliseconds happen because the timestamps are assigned by MiniMon, not by the transceiver. Because readers send variable length messages, MiniMon cannot optimize serial I/O on the message length. Instead, it has to rely on hardware interrupts to get data from the serial ports, which are at the mercy of a lot of system related tasks that dictate when they can fire. Therefore MiniMon can process a batch of several tag records in microseconds and assign them all the same millisecond timestamp.

Related Questions

What is your question?