For testing purposes can I store multiple sets of axis settings (PID and trajectory)?
PMC’s Motion Dialog Library functions MCDLG_SaveAxis and MCDLG_RestoreAxis allow the programmer to save and load an unlimited number of servo setting initialization files with an application. Some of our grapical software utilities like the Servo Tuner also allow the user to save and load multiple different sets of PID and Trajectory parameters for each axis.