Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How can I use multiple GPIB Interface cards with Sicl and HTBasic?

cards gpib htbasic interface
0
Posted

How can I use multiple GPIB Interface cards with Sicl and HTBasic?

0

Starting with the 9.0 version of HTBasic, there is nothing special that needs to be done. The new HPIBS driver supports multiple instances of the driver. Example: 10 LOAD BIN “HPIBS;DEV gpib0 ISC 7” 20 LOAD BIN “HPIBS;DEV gpib1 ISC 8” 30 LOAD BIN “HPIBS;DEV gpib3 ISC 13” With versions earlier then 9.0, it was necessary to make copies of the HPIBS driver, so that there can be multiple HPIBS.dw6 files with different names. Next each Interface loaded needs to use a different file for its driver.