How do I get Sbackup to work with NetWare 3.12/4.x?
Perform the following steps to make the Sbackup utility work with NetWare 3.12/4.x: • Install the latest sbackx.exe update from the Novell Web site. • Make sure the correct disk driver and ASPI driver are loaded for the installed tape drive. • Add the following line to the startup.ncf file: Set Reserved Buffers Below 16 Meg = 200 • Add the following lines to the autoexec.ncf file: Load TAPEAI.DSK SCAN FOR NEW DEVICES Load TAPEAI.DSK Load TSA312 (for NetWare 3.12) Load TSA410 (for NetWare 4.1x) Load SBACKUP • Follow the screen prompts. For PowerEdge 51xx-XL, 4×00, and 6×00 systems, the tape drive is on the second AIC78x0 controller. For PowerEdge SP/XE or SP-2/XE-2 systems, the built-in NCR 53C810 controller requires the dfs311.dsk or dfs400.dsk drivers revision A02 or later from ncrscsi7.exe from Dell’s BBS (512-728-8528) or Web site (www.dell.com). NOTE: Sbackup does not support IDE tape drives.