Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How do I prevent hydrate and freeze-out checks in simulations where they are likely not to occur (e.g., amine systems)?

0
Posted

How do I prevent hydrate and freeze-out checks in simulations where they are likely not to occur (e.g., amine systems)?

0

You can disable the simple hydrate and other freeze type checks from occurring within the streams and blocks of all flowsheets associated with an environment by unchecking the “Check Freeze Out” button on the Options page of the environment dialog. You may also adjust how close to freeze conditions you actually must be before a warning is issued by changing the temperature delta value. Disabling this check does not affect freeze out calculations in Analysis objects.