How is the Parallel Swathing Option configured to balance skip and overlap?
The end of boom nozzles are usually set to apply chemical past the boom edge. Therefore the effective spray area is slightly larger than the boom width. To minimize skip and overlap, configure the swath width to the effective spray width. The effective spray width is dependent on the end boom nozzle spray characteristics.