Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

I have difficulties in running a simulation of system A 12 (buffer tank system with fresh water station). What should I do?

0
Posted

I have difficulties in running a simulation of system A 12 (buffer tank system with fresh water station). What should I do?

0

Unfortunately, the volumetric flow rate for the secondary loop is not automatically adjusted for the defined collector area. Once set, the volumetric flow rate stays the same, even if the collector area is changed. This makes it necessary to correct the volumetric flow rate for the secondary loop whenever a change is made in the size of the collector area. The corresponding dialogue for entering the volumetric flow rate for the secondary loop can be accessed via the Parameters > Solar Loop menu.