Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

I selected the adapter, protocol and then CONNECT, why is noting happening?

0
Posted

I selected the adapter, protocol and then CONNECT, why is noting happening?

0

A. Make sure the key is on, Make sure the Datalink adapter is properly connected, If you are using a USB to Serial adapter, Make sure the com port settings in Control Panel System Devices is correct. If any module is responding at all, the module you are trying to connect to may be faulty or the fuse could be blown. An example would be no engine data at all but I do see ABS data in the data view tab… This would suggest that the engine, engine data link wiring, or engine ECM Fuse is defective If you have connected to other vehicles previously and no settings were changed, and the fuses and wiring is OK, Try disconnecting and switching to another protocol, The module may not support J1708 or J1939. look at the bottom of the PF-Diagnose screen for an error message, Email that message to PFSupport@rogers.com and include the session log file PFDiagnoseSession.log found in the Diagnostics folder in My Documents HINT: A good indicator that the ECM is powered and communicating OK, is the che