Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Is calculation of convective heat exchange and optical calculation of glazings in combination with solar shdaing devices in accordance with prEN 13363-2 or ISO 15099?

0
Posted

Is calculation of convective heat exchange and optical calculation of glazings in combination with solar shdaing devices in accordance with prEN 13363-2 or ISO 15099?

0

Yes it is, from WIS version 2.0. prEN 13363-2 has a more limited scope than ISO 15099: only normal solar incidence angle, no direct transmission of solar radiation through the blinds. WIS covers the wider scope of ISO 15099.