What analytical methods apply for samples from Method 0031 and what are the primary target analytes?
Apply a thermal desorption method such as SW-846 Method 5041A for sample preparation of VOST samples. Conduct sample analyses by gas chromatography/mass spectrometry using procedures such as described in SW-846 Method 8260B or TO-15 (sections 9-11). The primary target analytes are those listed in TO-15, table 1. You must document and report the methods and procedures used and the applicable quality assurance results.