What are environmental conditions for using Prescale?
A. The following condition is recommended for Prescale usage: Temperature 20 ~ 35C (68~ 95F) and humidity 35~ 80%RH Measurement up to 180C is available, however, the color density as well as the absolute values of the pressure cannot be guaranteed. Please note that the PET base gets soft at 80C. The lowest temperature for possible use is around -20C. Accuracy: 10% or less based on density values. For pressure values 10% or higher. The use in water or oil Protect the film in a sealed poly sack or be careful to keep the coated side out of water or oil. The use at high temperature For a few seconds pressure application, sandwich the Prescale film between heat-resisting films. You can measure pressure even at high temperature as long as the heat-resisting material protects the Prescale film and it does not transmit the heat to it. For jet pressure measurement Protect the film in a sealed poly sack or cover the film with a protective sheet. Prescale is a highly sensitive film that reacts to