Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the data acquisition rate for a CASP?

acquisition casp Data rate
0
0 Posted

What is the data acquisition rate for a CASP?

0
0

“Data acquisition rate” is not a very applicable term for CASP. However, the open circuit terminal voltage of the battery being processed is measured once per second throughout the processing cycle. In constant current mode, the current control point is set by the microprocessor and maintained at that value by an analog feedback loop. Thus, the current control has no digital “data acquisition rate” associated with it.