Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the long-term stability of the ASF14xx gas flow sensors?

0
Posted

What is the long-term stability of the ASF14xx gas flow sensors?

0

Sensirion has carried out extensive “accelerated ageing tests” with the ASF14xx and ASP14xx gas flow and differential pressure sensors. Among them are international standard tests like: JEDEC JESD22-A104-A (Temp:125°C and -40°C, 1’000 cycles, retention period 20 minutes per step, total 14 days) JEDEC JESD22-A101-B (85°C/85% RH/1000h) DIN-50021ss (salt water spray test) JEDEC JESD22-A110-B (125°C/85% RH/230 kPa/96 h) IEC 68-2-6 (DIN 60068-2-6) (Vibrations: 10 ms-2/25-2000 Hz) Please contact Sensirion for further details.