Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why dont I get any laser power unless I press the Test Mark button first?

0
Posted

Why dont I get any laser power unless I press the Test Mark button first?

0

Run the following test to see if you have an address contention problem between the FLCC and the WinMark Pro PC: 1. Power up the Marking Head and initiate a Test Mark using the Test Mark button on the Marking Head and verify that the laser and Marking Head are operating. 2. Verify that the WinMark Pro software is closed. 3. Open the DigScope utility that is located in the WinMark Pro program group and folder 4. Press the Toggle Lase button and verify the window shows LASER IS ON 5. Drag the Laser Duty Cycle slider back and forth across the range of values and verify that the laser power is being changed. You should be able to set the slider at its leftmost position and see little or no laser output. If the laser output power doesnt respond to the slider settings, then you are probably having an address contention problem between the computer and the FLCC. This may be resolved as follows: 1. Close DigScope and go into the Windows Control Panel and open the System utility. 2. Click on th

Related Questions