Why Prime chargers provide a Thermal run away protection?
The proper charge voltage relates to the battery temperature, a warmer battery requires a reduced voltage, otherwise, it may bring a destructive result if the charging current increased, the battery heating will be increased under a loop feeding on itself. To be prevented Thermal run away for a battery, the Prime smart chargers used unique programmed charging algorithm to monitor the relationship between the CV voltage and charging current; If detected the Thermal run away occurred, the charger will promptly switch to Float charging stage or shut down the charging progress; Also, the maximum charging timer built into program. And the temperature sensor is an option for users to monitor the battery temperature as well on Prime smart battery chargers series.